When considering the introduction of a storage location management system for molds and jigs, simply enabling the reading of rack numbers via smartphones is not sufficient. The racks that can “hold” heavy molds are not always the racks where they are “allowed” to be placed. It is essential to check weight, external dimensions, supporting method, transport equipment access routes, and rack damage, and to design a system that performs one-to-one reconciliation between the physical item and the bay it occupies. This article assumes a mold and jig warehouse in a Thai factory, and concretizes the process from physical inventory and requirements definition, to selection and acceptance testing.
The Issues to be Solved by Storage Location Management of Molds and Jigs
The existing Guide for Implementing Mold Management Systems covers ledgers for ownership, shot count, maintenance, and lent molds. The article Tool Checkout Control System discusses check-out, return, and usability for each item. The scope of this article is the physical storage that comes before and after those processes. It addresses the moment when a mold returns to the mold warehouse: to which bay can it be safely placed? Was it actually placed in that bay? Can a crane or forklift comfortably approach the mold when it needs to be retrieved? This mechanism is designed to solve those three challenges.
Storage issues in mold warehouses go beyond “searching takes too much time.” Issues cascade: temporarily stored molds might remain registered to their original rack in the ledger, similar molds get misplaced into the wrong bay, heavy molds are placed on racks with unclear load capacities, or molds are retrieved for the next operation without recording damages found upon return. Deploying only a search application may just make it easier to quickly display the wrong rack number. Placement methods, rack capacities, and movement records must be addressed together.
Delineate responsibility between “mold ledger,” “checkout ledger,” and “storage location.” The mold ledger is the master for type, item, owner, target product, weight/dimensions, and maintenance status. The checkout ledger covers who transported what and when to which line. Storage location is the master for building, zone, rack, tier, bay, storage conditions, and current occupancy by a physical item. Even among these, it is crucial that the same fields are not repeatedly manually corrected by different parties.
| Managed Item | Primary Key | When It’s Updated | Impact of Error |
|---|---|---|---|
| Mold/Jig Item | Item ID | Registration/Modification/Disposal | Confusion between different molds |
| Rack Bay | Location ID | Rack modification/Damage/Closure | Molds stored in unsuitable locations |
| Occupancy Relation | Item ID + Location ID | Inbound, Transfer, Outbound | Discrepancy between physical item and system |
| Movement Event | Event ID | Upon actual movement completion | Unable to track who moved what, when |
Register Racks as “Storage Capacity” Rather Than Just an “Address”
Assigning a rack number such as A-03-02 in a mold warehouse does not certify its ability to safely store a mold. Each bay should have registered permissible load, internal width/depth/height, support surfaces/fittings, shelf height, load/unload direction, compatible handling equipment, and clearance around it. On the mold side, store actual measured weight (including lifting gear), dimensions, any protrusions, center of gravity and support information, and presence of dedicated pallets/base frames. The necessary attributes will differ depending on actual storage methods, and should be determined collaboratively by equipment manufacturers and on-site managers based on physical inspection. Simply entering values into software screens does not guarantee rack safety.
Storage suitability at minimum should check: “Is the weight within verified limits for the rack, tier, bay, and handling equipment?”, “Do the mold and its frame fit within the bay opening?”, “Are the support points stable?”, “Is the handling route secured?”, and “Is the candidate bay not marked out of service?”. For conditions such as center of gravity, cantilevered loads, point loading, seismic countermeasures, or floor loading that can’t be determined by simple numeric comparison, consult specialists and master-register only the approved combinations. This avoids the on-site misconception that “as long as the weight fits, it’s fine.”
The UK’s HSE recommends that storage equipment is designed and constructed to withstand loads, the reporting and regular inspection of damage, and protection from vehicle impacts. SEMA explains the display of rack safe working loads, advising verification with the manufacturer or specialist if these values are unknown. These are practical references for requirements definition and not statements of Thai legal compliance. The factory is responsible for ensuring actual equipment suitability and compliance with local laws.

Separate Shelf Candidate Priority from Safety Conditions
When the system returns multiple locations as candidates, first determine suitability, then rank based on work efficiency. It is reasonable to want to place frequently used dies near entrances, group dies used on the same line, or consolidate vacant locations, but these reasons must not take priority over weight or support conditions. Candidate ranking does not have the authority to override “safety approval”; rather, it is used to sort approved locations by ease of work.
If heavy dies concentrate on the lower levels of the same rack, you must check not only suitability at the location level, but also the overall rack load and floor load transfer. In some cases, the rack manufacturer’s specifications will define load conditions for not just locations but also for levels, bays, or columns. Avoid system designs that simply total the maximum values for each location and judge “there is still margin.” Instead, use layout conditions approved by equipment staff. Clearly indicate whether the die weight and location load values are in the same unit and whether they include the weight of stands or accessories.
When temporarily placing dies on the floor, do not allow unlimited “temporary storage.” Define safe temporary storage areas as locations, confirming their capacity, separation from aisles, and transport equipment access. Temporary storage should have time limits and reasons for use, with expired items listed. However, even if there is a notification of overdue items, this does not mean operators may move them on their own. Moves should be made with an appropriate transport plan and safety check.
If a special stand is required for the die shape or use, identify the die and stand as a set. Define in the master data whether the stand can be used by another die or if its condition needs checking. Even if the system shows “the die is in the rack,” if the stand is under repair, safe re-storing or transport cannot be performed. To prevent only tracking dies during retrieval and forgetting the stand on return, display missing sets on the screen.
Never Count “Unknown” as Accepted During Storage Suitability Checking
Old molds may have missing weight information, post-modification dimensions may not be updated, or load plates on racks may be illegible. It is dangerous if the system returns “available” using defaults in such cases. When weight, load bearing, or bay damage is unknown, exclude these as storage candidates, routing them for physical confirmation and equipment manager approval. By distinctively recording “unknown” and “non-compliant,” you can list master data needing improvement.
Even for the same mold shape, whether it is on a pallet or not can change its footprint and height. Manage not only the core mold weight, but also the gross weight/dimensions including pallet, base, and lifting hardware. Additionally, ensure crane capacity along the lifting path, and rack capacity at the destination, are confirmed separately. If only one of these is suitable, the transfer should not proceed. On-screen “candidate display” does not replace field safety checks—design it so that operators follow approved procedures.
Location Hierarchy Should Match On-Site Readability
Use a basic hierarchy of Building → Zone → Rack → Tier → Bay, and ensure labels are physically visible to operators. If two molds are stored side-by-side within a bay, or where one floor space is shared by several molds, introduce finer position indicators such as left/right or front/rear. Excessive granularity, however, makes it hard for workers to find the correct code. The smallest unit should be what can be unambiguously identified on site to prevent misplacement.
“Present in the mold warehouse” does not guarantee immediate retrieval. Bays where the front row must be moved to access the back are subject to access restrictions in the depth direction. For large molds, storage planning should account for crane traveling range, hook height, forklift turning clearance, temporary placement areas, and extraction sequence. Even if the rack is strong enough, if the access routes are blocked, outflow may still be impossible. Note also that aisles must not count as storage space.
GS1 explains the distinction between GIAI (Global Individual Asset Identifier) for items, and GLN (Global Location Number) for physical locations. If using GLN in physical rack labels, the AI (414) is recommended. Use of GS1 keys is not mandatory for an internal mold warehouse. If sharing identifiers with overseas sites or outsource partners, consider adopting GS1; for internal use only, proprietary non-colliding IDs are acceptable. Consistency between label display, barcode values, and database keys is what matters most.
Inbound Operations Must Match Both “Item” and “Location”
Do not update item status to “in storage” just by registering planned inbound. Only upon actual placement, scan both the mold/jig item label and the rack bay label in order, reconfirming bay suitability checks, vacancy, occupancy/disabled status, and then confirm the movement event. If labels are damaged and unreadable, do not simply allow free text entry: provide an approved alternative identification flow. Even if suitability is passed, the system should allow the operator to cancel if visual checks on site reveal rack deformation or storage overflow.
If only one item is stored per bay, enforce exclusive occupancy at the database level. For shared zones, clarify by capacity unit and position. If two users simultaneously attempt to receive into the same vacant bay, reject the latter and prompt reselection. “Vacant” displayed on screen alone cannot prevent conflicts. For offline configurations (batch data collection), collisions on sync are likely; so define provisional registration vs. confirmation, responsibility for resolving conflicts, and physical reconciliation steps in advance.
For outbound operations, scan the item first, then the bay, and check consistency with the expected location. Avoid manually overriding physical location in the system just because the item is missing. Instead, record “location mismatch” as a specific exception, investigate adjacent bays/temporary or maintenance zones, and then correct. Review the number and reasons for exceptions weekly to identify entry points of unrecorded movements.

On Return, Separate Storage Suitability from Usability for Next Operation
A returned mold is not necessarily “ready for use” immediately. Record external damage, rust, missing accessories, incomplete cleaning/rust-proofing, and pending inspection. But physical storage suitability and operational status are not the same. While waiting-inspection molds may be placed in quarantine areas, they must not count as vacant in standard racks. Define allowable locations by status, and prevent reinstatement to general use until maintenance manager’s approval is given.
For return photos, set camera angle and distance in advance for consistent damage comparison. Don’t store unlimited images—focus on photographs only for exceptions or spots needing detail. Decide if accessories should be tracked as separate items or as checklist items within a set. To prevent issues where accessory shortage is only noticed at the next usage, systems should not only check via return screens but confirm actual accessory placement as well.
Racks themselves also have status. If collision marks, bends, anchor anomalies, or missing load signs are detected, allow the bay to be put “out of service” and instantly exclude it from candidate suggestions. Tie inspection records to both rack and bay, so the equipment manager can decide if the issue is limited to one shelf or the whole rack. US OSHA warehouse safety materials recommend isolating damaged racks, preventing storage above load ratings, and placing heavy loads at lower/middle levels. Again, these are references for discussion, not substitutes for local regulations.
The Data Model Must Balance “Current Location” and “Movement History”
A table that overwrites only current location can’t trace causes of misplacement. Always record movement events with item ID, old location, new location, operator, time, transfer method, status, reason, and approver. Current location is updated based on events. Corrections express as new correction events, not deleting prior logs. This is not for excessive personal monitoring, but to reconstruct physical item checks and rack assessments. Access rights and retention periods should follow company policy.
Attributes such as weight and dimensions are received from the mold ledger; maintenance systems inform storage prohibition or inspection clearance; the check-out system is given location and outbound permission. ERP asset numbers may not always correspond one-to-one with physical item IDs, so maintain a separate mapping. When a mold is on the production line, treat the line or workstation as a location, or distinguish by separate “checked-out” status instead of “no rack assigned.” In any case, enforce that the same item does not exist in two places simultaneously.
| Status | Physical Location | System Treatment | Next Action |
|---|---|---|---|
| In Storage | Approved rack/bay | Outbound candidate | Match against instructions/reservations |
| In Transit | In transfer task | Does not occupy rack | Confirm drop-off location |
| In Use | Line/equipment | Rack is freed up | Manage return plan |
| Awaiting Inspection | Designated quarantine | Prohibited for use | Maintenance review |
| Location Mismatch | Not confirmed | Hold allocation | Physical investigation |
| Disposed/Returned | Off site | Excluded from list | Retain audit trail |
In RFPs, Specify Demonstration Scenarios—Not Just Number of Screens
Three Lists to Prepare During Physical Inventory
Before system deployment, prepare separate lists for molds/jigs, storage locations, and unresolved location discrepancies. The item list should include ID, model, owner, measured weight, dimensions, pallet/base, photos, and current use status. The rack list should detail area/bay, nameplate, verified load, internal dimensions, support type, handling direction, damage/disabled status. Discrepancy lists gather “physically present but not listed,” “listed but not found,” “multiple labels attached,” and “duplicate rack codes used for different locations.” Don’t forcibly overwrite discrepancies with assumed correct values; assign a responsible resolver and deadline.
Double-checking the same bay by two independent operators during inventory helps discover reading mistakes. If heavy molds need to be moved, avoid dangerous transfers solely for inventory—check labels in tandem with normal safe moves. Never trust dimension/weight values from drawings or old ledgers without cross-verifying with modification histories. To avoid mixing measured and estimated numbers, record “source,” “date measured,” and “approver” columns.
Initial data quality directly affects post-go-live search accuracy. It’s not necessary to wait until all item data is complete, but check that IDs, current locations, and storage suitability attributes for items in the focus areas are verified before go-live. One approach is to manage unverified items in a separate area and only move verified groups to the system’s confirmed inventory. If on-site movement events aren’t recorded from day one, data will already be stale the day after initial inventory.
Choosing Display, Permissions, and Communication for Thai Factories
Set screen and label language—Thai, Japanese, or English—according to actual workers on day and night shifts. Keep shelf codes as language-independent short strings and switch explanatory text on-screen. Error messages like “storage not possible” are inadequate; indicate briefly if the problem is overweight, dimension mismatch, disabled rack, occupied, maintenance pending, or master data unverified, and display who to contact. To avoid operational differences arising from translation, involve workers of all languages in user acceptance testing.
Set permissions for each role: field operators confirm inbound/outbound and report exceptions; warehouse managers resolve location discrepancies; equipment staff approve rack capacity/disabled statuses; maintenance handles mold condition; admins handle master data changes. Avoid allowing the same person to raise rack capacity and then immediately store an over-limit mold. For small plants where separation of duties is difficult, require change reasons and post-change review.
If wireless coverage is weak in the mold warehouse, decide whether to allow offline inbound scans or require confirmation at a connectivity point. Never leave the physical item updated ahead of the system indefinitely. Visibly display unsent events on terminals, and set rules to prevent double storage before sync. For paper fallback during outages, clarify who is responsible for checking and inputting after recovery.
Even if a vendor scores “barcode-compatible” or “location management-compliant,” it doesn’t guarantee your heavy molds can be safely stored. Attach anonymized samples of real mold dimensions/weights, rack layout diagrams, handling equipment, and known exceptions to your RFP, and specify demonstration scenarios. For example: “placing an overweight mold,” “two users concurrently try to store in the same bay,” “unreadable label,” “immediate attempt to store after disabling a rack,” “trying to return maintenance-pending mold to a standard rack.”
For price comparison, estimate not only licensing, but also physical rack measurement, material/durability of labels, terminals, wireless, master data setup, integration with existing systems, frontline training, night shift support, and maintenance after rack changes—using the same scope across vendors. If the mold warehouse is exposed to heat, oil, or dust, have labels and terminals tested on site for durability. Costs will vary by plant size and equipment, so typical rates aren’t specified here. List “assumptions” and “excluded work” on your comparison table to minimize surprises after ordering.
Deployment method is also a selection item. If standard location management features in ERP or EAM can handle rack bays and storage conditions, minimum extension is possible by leveraging them. If standard only covers movement history and can’t handle weight/dimensions/support or dual scanning at inbound, connect a dedicated shop-floor app for mold storage. If using a WMS designed for general warehouses as-is, check if its serialization and packaging assumptions match “individual molds.” Decide primary business events and data first; compare product names afterward.
Acceptance Testing: Match Physical Item, Rack, and System Display
For acceptance, do not simply check “was able to register.” Select test molds, measure weight/dimensions, and provide correct racks, overweight racks, dimension-incompatible racks, disabled racks, and already occupied racks. Scan both item and rack labels on the device, confirming allow/deny responses match design. Afterwards, reconcile the physical position, label, and current location on-screen for all three. Test full inbound, outbound, internal transfer, and return cycles to confirm history is saved.
Also include in tests: network outages and restoration, device battery depletion, double scans, label reissue, changes in item weight due to mold modifications, and rack damage updates. Especially confirm that racks previously approved do NOT remain allowed after mold weight is raised. Upon master data changes, review already stored molds for continued compliance. If any non-compliant storage already exists, stopping only candidates for relocation does not resolve all issues.

Pass/fail conditions can be quantified: for all tested items, “zero double occupancy of locations,” “zero commits to noncompliant bays,” “screen and reality match after exception handling,” and “disabled racks never appear as candidates” must be mandatory. Efficiency metrics like search-time reduction should be compared using your own current values for the same mold group and shift. Never use notional industry averages; document sample size, measurement conditions, and shift differences.
Phased Introduction: Start with One Mold Warehouse and One Movement Route
After Go-Live, Don’t Only Watch “Search Speed”
Search time is an easy metric, but if that’s your only yardstick, you might mistakenly credit a system that quickly shows erroneous rack numbers as a success. Assess screen-physical match rate, cases of mismatched locations, unrecorded temporary storage, attempted placements in disabled racks, count of bays with unknown load capacity, and undetermined damage on return. Also, do not simply count necessary denials as “system errors”—correct denials are evidence of safety measures working.
During improvement meetings, don’t blame workers based solely on counts. If attempted placements in disabled racks are high, root causes may include rack shortages, label placement, candidate order on screen, or movement route constraints. Inspect exceptions on site and decide whether to rearrange racks, update master data, or revise screen guidance. Continuous alignment of physical work and data is what enables sustained use of the storage system.
Do not implement rack layout changes as just a system change. Treat label removal, new label application, mold relocation, spatial and load reconfirmation, and a follow-up inventory all as one change operation. If both new and old rack codes are simultaneously valid, returned molds may inadvertently be placed back in old locations. Freeze the relevant bays during changeovers, set the restart schedule, and have a supervisor confirm the physical situation before reactivating. For repaired racks, never just remove the “disabled” flag—log details of the repair and its recertification.
When transferring between sites, record the period from removal at the origin rack until placement in the destination rack as “in transit.” Leaving the mold showing in an “empty rack” at either factory while it is actually in transit can lead planners to mistakenly allocate it. For outsourced storage, decide contractually and operationally whether the partner’s rack codes are shared, or only a general “external storage” status is needed. If sharing unique IDs, design the system to prevent duplication between sites and misassignment upon return.
Thus, even if starting with just one area, layout the entire process including movement, disablement, repair, and inter-site transfer status at design time—even if deferred for initial deployment. Feeding back unexpected on-site cases into documentation helps inform scalable roll-out conditions.
Registering all factory molds at once risks overwhelming the system with old weights and misaligned rack codes. Choose one storage zone, complete physical inventory, check rack capabilities, apply labels, establish in/out workflows and exception handling, and then expand. During proof-of-concept (PoC), don’t indefinitely keep dual input between paper and system; decide exactly when to designate the master record. On cutover day, confirm the identified locations of all items, and set unverifiable molds aside as “unknown.”
Involve at least warehouse, mold maintenance, production management, safety/equipment, and IT in the project. Warehouse staff check operation practicality, production management verifies searchability for next use, equipment staff check rack capacity and movement routes, maintenance confirms return conditions, and IT verifies master data, permissions, and integration. Put a single approval matrix in place so “who can release which rack” never gets ambiguous later.
The existing article, Mold Life Prediction and Maintenance Planning, dives deeper into maintenance and lifespan predictions. The storage system described in this article takes those determinations, and ensures unusable molds are excluded from outbound candidates for normal racks. There is no need to replicate maintenance algorithms or shot count ledgers in the storage management screen.
Judgment Table for “Actual Item-Based” Confirmation at Selection Meetings
Before requesting a system estimate, stakeholders should agree on which information the shelf suitability judgment is based. For example, is the mold’s mass a design value from the drawing, or a measured value after modification? Is the rack’s capacity the specification at construction, or a value recognized by the manufacturer for the current rack configuration? For transportability, have you confirmed not just the crane’s rated load, but also the sling, hook height, and the space available for swinging and landing? If the source of information is unclear and you enable automatic judgment, a seemingly accurate screen may hide judgments based on weak grounds.
Create the following judgment table, and for each item, classify as “Confirmed,” “Needs Confirmation,” or “Not Suitable.” Even if the weight and shelf dimensions match, you cannot store the mold if its bottom cannot stably rest on the beam. Conversely, a shelf frontage previously considered unsuitable in old records may become usable after confirmation by equipment staff and necessary repairs. It’s important to keep records of approval grounds and effective dates, and not treat only the on-screen judgment results as permanent facts.
| Confirmation Item | What to check with actual items/docs | Control in the system |
|---|---|---|
| Mold mass/shape | Measured values post-modification, with stand/accessories | Exclude from candidates if unverified |
| Rack capacity | Manufacturer docs, nameplate, current beam setup/damage | Unselectable when out of service |
| Support/stability | Bottom, support points, receivers, anti-tip/slide | Allow only approved combinations |
| Transport route | Used equipment, corners, aisles, sling height | Exclude unreachable locations |
| Actual storage | Item/shelf labels, occupancy, temporary placement | Confirm location after double check |
These judgments do not replace equipment or safety experts. The system is a tool to reflect confirmed judgments in field operations and to allow tracing of rationales later. Registering a new mold, relocating racks, changing beam locations, and replacing transport equipment are triggers for re-evaluation. Updating only at the annual inventory is not enough to keep up with rapid changes in mold storage.
Embed Responsibility for Suspension, Exception, and Resumption in the Screen
If a worker finds rack deformation during storage work, they should be able to report that shelf slot as immediately out of service. However, it’s better if resumption cannot be performed instantly with the same permissions. The equipment manager checks the damage area, records necessary repairs and inspections, and the person in charge approves reuse before the slot returns to candidates. By separating ease of reporting and resumption control, abnormalities are less likely to be hidden.
If a mold label cannot be read, do not confirm receipt with a blank item ID. Identify with model number, photos, engravings, and maintenance history; if issuing a temporary ID, establish a procedure to integrate it into the official ID later. Avoid visually confirming similar-looking molds. If shelf labels are unreadable, do not simply use a nearby shelf number, but have a responsible person confirm the position and reissue the label. Hidden buttons to easily bypass exceptions undermine the meaning of double checking.
If a mold scheduled for use is in an inspection-pending area, do not simply overwrite its status citing urgent production orders. Return the “reason for unavailability and inspector” to production control, and allow decisions about alternate molds, maintenance priority, or schedule changes. Being able to take an item from the shelf and being allowed to use it in production are separate judgments. Even when allowing removal, distinguish between taking out for inspection/repair and taking out for line input.
Boundary Conditions to Test with Real Data
Use acceptance test samples not only for the easiest standard molds. Include molds near the limit of shelf dimensions, those with offset centers of gravity, those needing special stands, those storing accessories separately, and those with weight changed due to modification. Have field supervisors select actual items and confirm transport equipment and shelf conditions, then test only within safe ranges. There is no need to demonstrate unsafe storage; it’s enough to confirm nonconforming candidates are rejected on terminals.
For shelves, prepare slots with available, occupied, suspended, unknown load, label damage, and blocked transport route statuses. When multiple conditions overlap for one slot, see which reason the screen prioritizes. For example, warning only about “occupied” might overlook that the shelf is out of service due to damage. Show essential information to operators simply, but allow supervisors to trace detailed rationales.
Test results should record not only the system’s grant/deny responses, but also the final actual position, movement events, shelf occupancy displays, mold status, and exception handling approval history. Keep the versions of the used shelf/molds as well. This allows tracking which conditions were met when racks were modified later. Do not assume passing samples guarantee suitability for all shelves/molds; clearly indicate untested types as remaining tasks.
Frequently Asked Questions
Can Warehouse Management Systems (WMS) be Used as Mold/Jig Storage Location Management?
If the WMS can handle individual item IDs, rack bays, load/dimension criteria, out-of-service racks, double scans, and movement history, it may be considered. However, WMS designed primarily for quantity and lot tracking may not adequately represent the nuances of individual molds or large-item movement requirements. Determine suitability through acceptance testing with actual racks and molds.
Should We Use Barcodes or RFID?
First, establish operational procedures to ensure sure matching of “item” and “location.” Barcodes are low cost and make the operator consciously aim the scanner, but are affected by dirt or visibility. RFID allows bulk reading, but needs field testing for read frequency/reliability in the presence of metal racks/molds and closely-packed items. Do not pick a technology in advance—test for misreads and missed reads in your actual environment.
What if Rack Load Capacity Is Unknown?
Never register or approve based on estimated values. Check manufacturer specs and nameplates. If still unknown, exclude from storage candidates until evaluated by equipment staff or a specialist. SEMA’s technical FAQ also advises contacting the manufacturer or specialist if rack load rating is unclear.
Where Is the “Current Location” of a Mold While on the Production Line?
Register the line or workstation as a storage location, or categorize check-outs as distinct from in-storage status. Avoid displays such as “location is blank, so it must be missing.” Distinguish in-transit, in-use, and awaiting inspection. Regardless of method, ensure no item ever has two simultaneous confirmed locations.
What Should Be Aligned When Comparing Implementation Costs?
Look beyond just software. Factor in rack suitability checks, physical measurement of molds, labels/devices/wireless, ERP/maintenance integration, training, exception handling, and maintenance—all under consistent scope. Costs differ if onsite measurements or rack repairs are needed, so don’t decide on fixed up-front quotes before survey.
Summary
A mold/jig storage location management system is, before a rack search tool, a mechanism for aligning actual items and bays regarding suitability, occupancy, and movements. Besides weight and dimensions, always check support, handling, and rack status, and double-match item and bay upon placement. Never treat unknown values or damaged racks as automatically approved; separate operational readiness from mere storage readiness upon return, and always complete physical acceptance tests as a key step.
If you are considering implementing a storage management system for your mold warehouse in Thailand, from rack inspection through to data items, terminal operation, and legacy ledger integration, you can consult TOMAS TECH even before requirement finalization. We help organize the necessary scope together, while confirming on-site handling sequences and rack conditions.
Reference Information
- GS1: GLN and AI(414) for Identifying Physical Locations
- GS1: Explanation of GIAI—Global Individual Asset Identifier
- HSE: Health and Safety Guidance for Warehousing/Storage
- SEMA: Rack Safe Loading and Inspection FAQ
- OSHA: Warehousing Storage Equipment and Load Cautions
- Microsoft Learn: Managing Assets and Functional Locations