When introducing pneumatic soft start and residual pressure exhaust valves, if you select based only on catalog phrases like “slow start-up” or “quick exhaust,” you may encounter issues such as unexpected cylinder movement, residual pressure remaining in branch piping after shutdown, or inability to explain the performance of safety circuits. This article targets automatic machines in Thai factories, separating normal start-up control from safety-related exhaust functions, and organizes the process from circuit investigation, specifications, testing, to maintenance. The first thing to decide is not the model, but which pneumatic zone you want to move to which state, in response to which stop request.
First, Separate the Three Functions
“Soft start” is a function that gradually increases downstream pressure when supply starts. It is used to suppress sudden cylinder extension or mechanical shock due to rapid pressurization, but this does not guarantee harmless movement. “Residual pressure exhaust” is a function that shuts off supply and vents downstream air to the exhaust port. However, pressure can be trapped in downstream check valves, closed directional control valves, cylinder chambers, tanks, or long hoses. “Safety-related exhaust” is a function that, as part of a safety function defined by risk assessment, removes pneumatic energy upon request and detects/controls failures. Simply having an exhaust port on a product does not make it a safety function.
SMC introduces the AV-A as a soft start valve that gently increases supply pressure at start-up. Festo’s MS6-SV and Parker’s P33 specify safety functions and connection/monitoring conditions for each model. Therefore, even if the names are similar, they cannot be replaced as equivalent functions. Comparing SMC product information and Festo product documentation, it is clear that identifying the product series and options must come first.
| Item Under Consideration | Main Purpose | Points to Confirm |
|---|---|---|
| Soft Start | Controls pressure rise during re-pressurization | Actuator position at start-up, pressure rise, switching conditions |
| Ordinary Residual Pressure Exhaust | Releases downstream pressure before stop/maintenance | Exhaust range, trapped pressure, pressure confirmation, isolation procedure |
| Safety-Related Exhaust | Implements defined safety functions | Required PL, fault monitoring, diagnostics, piping zones, verification |
This distinction is also important for procurement. A request like “one valve to exhaust residual pressure” does not clarify whether it is for ordinary maintenance or for protective stop when a safety door is opened, making quotation comparison impossible. Separate the applications, and attach the necessary piping diagrams, electrical diagrams, and safety function specifications to the same RFP.

Why Stopping Air Supply Does Not Automatically Make a Machine Safe
Pneumatic equipment consists of multiple energy zones: supply source, filter/regulator, valves, manifolds, actuators, vacuum circuits, etc. Even if you shut off the main valve, downstream check valves may prevent backflow and retain air on one side of a cylinder. Vertical axis loads may lose holding force when exhausted and drop due to gravity. Conversely, if the non-exhausted side remains, it may move unexpectedly in the opposite direction. Mark each maintenance zone and hazardous movement on the drawing, and do not assume “if I exhaust here, the whole system is safe.”
When modifying existing machines in Thai factories, the actual equipment may not match the drawings. If there are field-added air tanks, bypasses, vacuum generators, check valves, or manual valves, the exhaust targets change. First, trace the piping from the pneumatic source to the end, assign identification numbers to each valve port and actuator chamber. For each state—power off, emergency stop, guard open, normal stop, maintenance isolation—measure where pressure remains. Measurement points should not be only immediately after the main valve, but also at representative far ends and suspected trapped locations.
While US OSHA lockout regulations do not directly apply as Thai law, they are useful as primary references for considering hazardous energy isolation and residual energy handling. OSHA requires management of unexpected start-up or release of stored energy during maintenance, and explains that bleed valves may be necessary in pneumatic systems. Local laws, customer requirements, and internal company rules must be checked separately. Refer to OSHA 1910.147 and OSHA guidance.
The Roles of Rod Locks and Exhaust Valves Are Different
A related article on pneumatic cylinder rod-lock selection focuses on mechanisms to hold the position of vertical loads during power outages, etc. The exhaust valves in this article focus on managing energy entering a zone from the pneumatic source and pressure remaining within the zone. If you want to exhaust without dropping the load, you need to evaluate a combination of holding mechanisms and exhaust procedures. Installing one does not automatically fulfill the function of the other.
Define Pneumatic Zones and Stop Requests Before Implementation
Whether you exhaust the entire system at once or only the cell where operators enter will affect valve size and restart procedures. For example, when cleaning the supply station of an assembly machine, stopping the adjacent transfer station as well would cause significant production loss. On the other hand, if there is backflow from a shared header, simply dividing zones does not achieve isolation. On the piping diagram showing zone boundaries, mark pneumatic supply, exhaust, backflow paths, pressure check points, and manual isolation points. If you use split operation, also evaluate actuators and workpieces that cross zone boundaries.
Next, define stop requests in a table. For normal stops, it may be necessary to hold the product after stopping. For emergency stops, stopping hazardous movement takes priority. When a guard is open, it may be necessary to remove energy from the zone accessed by the operator. For maintenance isolation, you need a procedure to isolate the air source and confirm residual pressure, without relying solely on electrical stop signals. If you combine all these into a single “OFF” signal, agreement on the stop state becomes ambiguous.
ISO 4414:2010 covers general rules and safety requirements for pneumatic systems and components, targeting design, modification, installation, maintenance, etc. ISO 13849-1:2023 covers design and integration methods for safety-related control parts, but does not automatically specify the required PL for specific equipment. Therefore, first define the machine hazards and safety functions, and determine the required PL through risk assessment. Then, treat the selected valves, input devices, logic, output devices, wiring, monitoring, and verification as a single safety function. Refer to ISO 4414 and ISO 13849-1.
Points to Check When Selecting a Soft Start Valve
The first check is the cylinder position at start-up. Which cylinders are extended/retracted at stop, and in which direction do loads or spring forces act? To which position do directional control valves return? Which axes move first as pressure rises? Do not simply write “all at home position,” but list multiple initial states such as power failure, air cut-off, and restart after maintenance. Decide whether it is acceptable to resume with the workpiece still gripped, or only after the operator has removed the workpiece from the jig.
Next, measure supply pressure, minimum operating pressure, maximum flow rate, downstream volume, and loads that start simultaneously. The soft start throttle adjustment range depends on the model, and the larger the volume, the longer the pressurization time. If multiple valves open simultaneously right after start-up, incomplete operation may occur at low pressure. In the field, set up a sequence to detect when pressure reaches the specified range and issue a run permit. Place pressure sensors not only on the supply side but also downstream as needed, and decide how to handle sensor faults and disconnections.
The SMC AV-A is a product that adjusts supply pressure rise at start-up, and bore size and operating pressure range differ by series and model. When selecting a model, check compatibility with the latest manufacturer documentation, and do not order based only on the old AV series name. The current SMC catalog also notes the discontinuation of the old AV series and guidance to successors. Check compatibility of replacement parts, brackets, piping direction, and coil specifications by model number. Refer to SMC AV-A and SMC product catalog.
Do Not Evaluate Only the Slowness of Pressurization
“Slow” does not always mean “safe.” With gravity loads or cylinders with pressure differences, there is a risk that holding force is insufficient at low pressure and movement occurs. If pressurization is slow, there is also a danger that the machine moves at a timing when maintenance personnel do not expect a restart. The values to be evaluated are: in multiple specified initial states, in what order and how much do cylinders move, and when does the run permit become valid. Test with synchronized camera and pressure logs, and do not simply adopt the manufacturer’s standard adjustment values.
Points to Check When Selecting a Residual Pressure Exhaust Valve
Exhaust valves have a flow path to stop supply and a flow path to vent downstream. When selecting, check not only supply side pressure/flow, but also downstream maximum volume, piping diameter, exhaust port, silencer, exhaust direction, exhaust noise, and conditions of oil, water, or dust. Exhaust speed is not determined by the valve’s rated flow alone, but also changes depending on hose, fittings, silencer, branches, check valves, and the open/closed state of downstream valves. If you require “dangerous pressure to be eliminated within a specified time” for protective stop, measure with actual piping and load.
Do not direct exhaust ports toward walls or operator work positions. For equipment where oil or drain is mixed in the air, consider exhaust treatment and maintenance frequency. Silencer clogging or poor replacement can affect exhaust time, so include replaceable layout and inspection methods in the specifications. If you add a silencer to reduce noise, re-evaluate exhaust capacity. For tanks or closed circuits that retain pressure after exhaust, set up individual bleed and pressure check points.
In processes where you want to hold the workpiece with air during stop, full exhaust may not be optimal. You may need to provide a separate holding mechanism to prevent workpiece drop, or design with zone separation. In safety-related stops, “wanting to hold” and “wanting to remove hazardous energy” may conflict, so clarify the prioritized safe state in risk assessment, and ensure mechanical, electrical, and pneumatic engineers agree using the same diagram.

Conditions for Using Safety-Related Exhaust Valves
If safety-related exhaust is required, define the entire sequence—from emergency stop or guard interlock input, through logic, safety output, valve, pressure drop, and stopping of hazardous motion—as a single safety function. Even if the valve catalog lists a PL or category, that value is not guaranteed for the entire machine. Factors such as wiring, fault detection, common cause failures, diagnostic testing, maintenance intervals, downstream piping, and actuator configuration all have an impact. Especially, a “valve off” signal does not necessarily mean “hazardous energy is gone.”
The Parker P33 safety exhaust valve documentation shows variations with and without soft start, external monitoring configurations, required controller connections, and supply conditions. The documentation specifies application limits based on ISO 13849-1 for certain configurations, but do not generalize those numbers to other P33 models or the entire equipment. Festo MS6-SV also has different safety functions and performance conditions depending on the series and model. The ROSS MDC series comes in both soft start and non-soft start versions. The comparison should be based not on brand names, but on the exact model selected and the system configuration. Refer to Parker P33 documentation, Festo MS6-SV documentation, and ROSS MDC operating instructions.
For example, in a design where opening a safety door triggers exhaust, you must define door switch status monitoring, exhaust valve fault monitoring, pressure drop time, timing for opening the door, and restart prevention after reclosing. Select and wire the door switch as a machine-guard safety device, and verify the actual safe state of the pneumatic area separately. For a circuit using a safety relay, see our safety relay selection guide. Even when using a safety PLC, do not substitute generic PLC screen displays for fault diagnostics.
Preventing Unexpected Restart
A configuration where simply resetting the emergency stop button after exhaust causes pressurization and operation to start can be dangerous. The safety function specification should state the reset location, line of sight, need for manual operation, pressure restoration confirmation, actuator home position, and workpiece status. Pressure rise by soft start and permission to start the machine cycle should be separate events. The same principle applies for power recovery, communication reconnection, and sensor fault recovery.
What to Include in an RFP Estimate
At the beginning of the RFP, include the target machine, pneumatic area, operating environment, supply air quality, piping diameter, pressure, downstream volume, maximum simultaneous load, and stop requirements. Next, clearly state whether the candidate valve will be used for “stepwise pressurization at startup,” “exhaust during normal stop,” or “exhaust as a safety function.” For valves with multiple functions, have the supplier specify the application conditions and adjustment/monitoring methods for each function separately. If specifying required PL, attach the machine’s risk assessment and safety function specification, and require the vendor to explain the validity of the entire circuit, not just the valve’s advertised value.
Do not limit the estimate comparison table to just the main unit price. Separate out filters/regulators, manual shut-off, lockout valves, pressure sensors, silencers, safety relays or safety PLCs, wiring, panel modifications, piping modifications, guard interlocks, spare parts, FAT, on-site SAT, and training. For existing equipment, also include costs for work during downtime, temporary piping for test runs, drawing updates, and creation of maintenance procedures in Thai. The lowest estimate does not necessarily mean the lowest total cost of ownership.
| RFP Item | Site Information to Provide | Evidence to Receive from Vendor |
|---|---|---|
| Pneumatic Area | Piping diagram, branches, tanks, check valves | Diagram showing exhaust target area and residual pressure study |
| Pressurization | Initial position, pressure, volume, permission conditions | Test plan for pressure rise and axis operation |
| Exhaust | Stop request, allowable time, exhaust port environment | Verification method for exhaust time including actual piping |
| Safety Function | Risk assessment, required PL, input devices | Official model, diagnostics/monitoring, verification documents |
| Maintenance | Isolation procedure, worker access | Lockout, pressure confirmation, training materials |
Once the model is decided, attach the manufacturer’s latest instruction manual and official flow diagram to the order documents. A short sales page from a distributor may miss piping orientation, minimum pressure, allowable power supply, pilot conditions, manual operation, state during failure, and inspection intervals. If proposing a successor model, do not accept “same body size” as sufficient explanation—request a table showing differences in function, flow rate, safety certification, wiring, and mounting dimensions.
What to Check in FAT
FAT is the opportunity to confirm that the required circuit and control have been built before delivery to the factory. First, compare the drawings and the actual equipment, and document with photos the model, flow direction, air supply, exhaust port, pressure sensor location, power supply, monitoring wiring, and silencer. Before energizing or pressurizing, confirm the isolation procedure for the area and the restricted entry zone. Testing should include not only normal operation, but also recovery from air shut-off, after power failure, after emergency stop, and after guard opening.
For pressurization tests, simultaneously record the pressure waveform on the supply and downstream sides and the operation of each axis. Change the initial position, combine with/without workpiece, maximum load, and minimum allowable supply pressure. Evaluation is not “looks slow,” but confirming there is no dangerous ejection, that operation permission is not given before pressure is established, and that there is no automatic restart after an error. Also record the valve adjustment screw positions and setting procedures.
For exhaust tests, record with timestamps from stop input to valve output, downstream pressure drop, and hazardous motion stop. Check the far end of cylinder chambers, tanks, and the back side of check valves—do not consider the test complete by measuring only immediately after the main valve. Also evaluate silencer specifications, impact on people at the exhaust destination, and exhaust noise. For fault injection tests, follow the manufacturer’s permitted range and safe test methods, and confirm that the safety function behaves as expected when sensors are disconnected or monitoring mismatches occur. Verification of PL should be performed by a specialist with the necessary design and reliability documentation.
A test-condition table should align each input with its measurement point, acceptance criterion and evidence. For normal start-up, record the procedure for isolating and restoring the air source, supply and far-end pressure taps, workpiece mass, initial cylinder position and conditions for issuing the run-permit signal. For emergency stop, log the input contact, valve monitoring signal, far-end pressure and state of hazardous moving parts on one timeline. Do not use a universal pressure or time threshold from this article: agree project-specific criteria from the risk assessment, actual machine specification and manufacturer instructions. Check instrument calibration and clock synchronization before the test so logs from different devices can be compared later.
For a retrofit, build the test sequence around possible states such as an axis moving after measured pressure falls, air remaining beyond a check valve after the main valve dumps, or a valve on another branch switching first during repressurization. The purpose is not to create hazardous motion. Remove the workpiece, provide mechanical support or isolate the area before testing; supplement faults that cannot safely be reproduced with drawings, manufacturer diagnostic procedures and analysis. When a test fails, do not merely change an adjustment and mark it passed. Record the cause, circuit change, effects on other stop states and scope of retesting in the change history. This lets FAT evidence be compared with SAT and future maintenance records.
Even if one model provides both soft start and exhaust, assess the two functions separately. For pressurization, verify start-up motion and the run permit after pressure is established. For exhaust, verify pressure decay after the stop demand and the conditions under which access becomes possible. Passing one function does not prove the other. Test repeatability at the adopted setting and expected operating range, not just at the ends of the adjustment range. Identify and document the final setting before handover. Define when replacement of a silencer or sensor requires retesting so later maintenance remains tied to the acceptance evidence.

SAT Reproduces On-Site Conditions
SAT is performed with the actual piping and air supply after installation. Even a valve that passed FAT may behave differently due to long hoses, added silencers, local supply pressure fluctuations, air consumption from other lines, or existing check valves. First, compare the actual equipment with the updated piping diagram, and eliminate any branch pipes or manual bypasses not shown on the drawing. Next, reproduce the same initial state and stop requests as in FAT, and record any differences in measured values. If the difference is outside the allowable range, do not just adjust the settings—identify the cause.
In Thai factories, include daytime and nighttime supply pressure fluctuations, compressor switching, humidity and drain, and restart after long-term shutdown as operating conditions. If air quality does not meet the manufacturer’s requirements, it can lead to valve failure or silencer clogging. Have local maintenance staff actually perform air shut-off, lockout, residual pressure confirmation, manual bleed, repressurization, and abnormal recovery on the equipment. Provide not only Japanese design documents, but also drawings, procedures, and labels in the language used on site.
Evidence to Record in Acceptance Documents
Acceptance documents should record the adopted model, serial number, drawing version, settings, supply pressure and load during testing, pressure measurement points, measuring instruments, pressurization time, exhaust time, actuator operation, results during failure, and corrective actions. A single “PASS” is not enough for future comparison during modifications. For safety functions, link the basis for required PL, equipment documents, circuit calculations, and validity confirmation records. Also define conditions for re-verification if settings are changed during maintenance.
Cost and Investment Decision Considerations
The price of this equipment varies greatly depending on diameter, flow rate, safety performance, monitoring configuration, and the extent of piping modifications, so it is more useful to collect comparable estimates under the same conditions than to show a single generic list price. Do not compare a standard soft start valve and a safety-related exhaust valve by the unit price of “one valve.” The former aims to improve startup quality, the latter to achieve a defined safety function, and the required control components and verification workload differ. Do not judge the value of safety solely by simple ROI from reduced stop time.
In operation, record and compare before and after introduction the history of sudden stops, rework during repressurization, workpiece damage, maintenance work, air leaks, and silencer replacement. Allocating costs for testing, training, and drawing updates makes it easier to avoid situations where only the person in charge can restore operation after startup. When approving equipment purchases, also confirm the allowable modification downtime, spare parts, local maintenance contact in Thailand, and delivery time.
Boundary Conditions Easily Overlooked in Existing Equipment Modifications
In existing machines, old manual valves or check valves may have been added downstream of the main valve. If you replace only the exhaust valve while leaving piping not shown on the drawing, downstream pressure may drop during test runs, but residual pressure may not be released for certain product types or manual modes. Even if it is difficult to test all product types and operating modes, at least identify the conditions that switch the circuit, record which combinations were measured, and which were confirmed by design review. Do not treat unverified states as “equivalent.”
In factories where multiple machines are connected to a shared header, also check whether isolating and exhausting only the modified machine will cause pressure fluctuations in other equipment. When repressurizing equipment with a large downstream volume, the common air supply pressure may temporarily drop. Even if adding a check valve suppresses the impact on the supply side, that valve may create a new trapped pressure. Including compressor capacity and tank volume, plan for SAT with simultaneous operation of surrounding equipment in addition to individual equipment testing.
On the control panel side, where you wire the existing emergency stop contacts is important. Simply adding a safety exhaust valve to a circuit that only stops the existing PLC output does not necessarily provide the required safety function. Draw the circuit diagram from safety input to output, reset circuit, monitoring signals, and state during disconnection, and confirm that the intended safe state is achieved even during failure. If the safety circuit of existing equipment is unclear, include its investigation as an item in the estimate.
Leave Maintenance Procedures and Change Management in Operation
During post-commissioning inspections, check for exhaust port blockage, silencer clogging, air leaks, manual operation part condition, and differences between pressure sensor display and actual pressure. Set inspection frequency according to the manufacturer’s instructions, operating environment, and risk assessment. If you temporarily disable the safety circuit for operation checks, clearly document alternative protection and recovery confirmation, and inspect to ensure the disabled state does not remain before returning to normal operation. If maintenance staff use different procedures each time, it indicates a lack of design and training.
Changes such as adjusting screw positions, switching to a different silencer model, extending piping, or moving sensor locations can affect pressurization and exhaust times. Even small part replacements should be judged with a change management table to determine which acceptance tests need to be repeated. For replacement of safety-related components, do not approve just because the name is similar—update manufacturer’s conformity documents, circuit calculations, and verification results. For failure history, record not only “valve did not operate,” but also power supply, input, supply air, output pressure, and diagnostic display in chronological order to make root cause analysis easier.
How to Write Acceptance Criteria Usable on the Shop Floor
Phrases like “starts up safely” or “residual pressure is released quickly” are easy to understand as design intentions, but are too vague as acceptance criteria for inspection. Acceptance criteria should be broken down into individual sentences covering the test’s initial state, operation, observation point, expected result, and recording method. For example: “Grip the workpiece at maximum load, set the supply pressure to the equipment’s allowable lower limit, then after cutting off the air supply, restore it. Record downstream pressure and vertical axis position simultaneously, and confirm that the machine cycle permission is not given before the specified pressure is reached.” Writing it this way makes it easier for both vendors and the factory to reproduce the same test. Do not copy specific allowable values from this example; determine them based on the equipment’s risk assessment and process requirements.
For exhaust conditions, the measurement point must be clearly specified, or the meaning will change. For example, “main valve outlet becomes low pressure” could overlook trapped pressure at remote ends. Specify locations where hazardous energy could remain, such as both chambers of a representative cylinder, tanks, downstream of check valves, or near jigs that workers may touch. Record any delay from stop request to measurement start, sensor sampling intervals, and calibration status of measuring instruments, so results can be compared with past tests. If the load moves even after pressure drops, include the axis position, speed, and state of holding mechanisms in the criteria.
For acceptance criteria during failures, limit the scope to events that can be safely reproduced on site. Possible scenarios include disconnection of monitoring pressure sensors, loss of control signals to valves, supply pressure drop, holding down the reset button, and communication recovery; get prior approval for test methods. Do not remove guards or leave dangerous loads unsupported just to induce failures. If the manufacturer specifies periodic tests, incorporate those procedures into the FAT and maintenance plan. For failures that cannot be injected, clearly state in the acceptance document how they will be verified—through design documents, analysis, or alternative tests.
In multinational factories in Thailand, translation of acceptance statements also affects quality. If terms like “exhaust,” “pressure release,” “supply cutoff,” “emergency stop,” and “maintenance isolation” are all translated into a single local word, the meaning of procedures can change. Match equipment numbers on drawings with local language operation instructions, and confirm that on-site staff can explain them on the actual equipment. Acceptance testing is not just a delivery ceremony; it is an opportunity for designers, equipment manufacturers, and local maintenance staff to confirm that they are all referring to the same safe state.
Frequently Asked Questions
Is a pneumatic soft start valve the same as an electric motor soft starter?
No, they are different. A pneumatic soft start valve controls the pressurization of downstream compressed air. An electric motor soft starter electrically controls the starting current and torque of a motor. Although the names are similar, the target energy, circuits, and test methods are different. Always specify “pneumatic” in the RFP and attach the relevant piping diagram.
Will installing an exhaust valve reduce residual pressure to zero?
It cannot be guaranteed. Residual pressure may remain in check valves, closed directional valves, tanks, or cylinder chambers. Confirm at each measurement point in the target area, and provide individual bleed points as needed. Do not consider the lockout procedure for maintenance complete just by indicating the main valve is open or closed.
Will installing a safety exhaust valve achieve PL e?
No. The application limits in the manufacturer’s documentation depend on specific models and conditions, and the required and achieved PL for the entire machine must be evaluated for each safety function. Design and verification must include input, logic, output, diagnostics, piping, and behavior during failure. ISO 13849-1 itself does not specify the required PL for individual machines.
What should be done if a vertical cylinder drops during a power outage?
If exhaust causes holding pressure to be lost, consider mechanical holding or rod lock separately. Test for load, holding direction, stopping distance, and each state of power failure, piping breakage, and restart, and define the sequence of exhaust and holding. Do not interpret the valve’s “soft start” as a fall prevention function.
What documents should be prepared first for a Thai factory?
Prepare the updated pneumatic circuit diagram, photos of the actual piping, list of initial positions and hazardous motions, stop request table, supply pressure, downstream volume, measurement points, and current maintenance isolation procedures. For safety-related applications, also prepare the risk assessment and required safety functions. With these, you can issue RFPs to candidates under the same conditions.
Summary
Selecting a pneumatic soft start and residual pressure exhaust valve begins by distinguishing between pressure control during startup, ordinary exhaust, and safety-related exhaust. Check the trapped pressure in the actual piping and the movement of the load, then define the required safe state before comparing models. During FAT and SAT, not only should the valve operation indicators be checked, but also record the pressure waveform, residual pressure at remote ends, hazardous movements, and behavior during failures. Even with the correct valve, if the piping zones and restart procedures are unclear, the intended benefits will not be achieved.
If you are considering air startup or residual pressure handling during maintenance for existing automated machines in a Thai factory, you can consult us via Contact Us even if you do not yet have the piping diagrams or specific problematic shutdown scenarios for the target equipment. We can help you organize the application, and proceed from clarifying the items to check in the RFP, FAT, and SAT.